{"product_id":"labconco-4-protector-airo-filtered-fume-hood-acid-sensor-115v-184410401","title":"Labconco 4' Protector Airo Filtered Fume Hood, Acid Sensor 115V - 184410401","description":"\u003ch5\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eLabconco 4' Protector Airo Filtered Fume Hood, Acid Sensor 115V\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThe Protector Airo Filtered Fume Hood requires no ducting and is available in 3' and 4' widths and 31.7\" and 37.7\" depths. Neutrodine Unisorb Filtration Technology offers comprehensive molecular filtration. eGuard communication software offers real-time monitoring on the user’s phone or computer. From a remote location, data such as usage authorization, filter saturation detection, sash position and temperature may be observed and managed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eErlab-proven Neutrodine Unisorb Filters are the heart of GFH Filtration Technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eBenchtop models include a fiberglass panelized liner. Models are available for carbon-only, carbon with acid sensor, carbon with formaldehyde sensor, or HEPA-only filtration. Filters are sold separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eEco-Foil air foil with aerodynamic Clean-Sweep airflow openings\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eCord-Keeper Slots on left and right side of air foil\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eRemovable front and side panels, and front and interior service access panels for access to plumbing and electrical wiring\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eBy-pass airflow design\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eGlacier white powder-coated steel exterior\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eChemical-resistant, fiberglass-reinforced, composite panel liner\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003ePre-wired vapor-proof LED lights for up to 63 foot candles rated for 50,000 hours\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eeGuard2 software communication\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eFactory-installed command module, fan button and light button\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eRoughing prefilter\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eBuilt-in exhaust fans to maintain 60 fpm face velocity at 16\" sash opening height\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eSound pressure of \u0026lt;60 dB(A) with sash at operating height and \u0026lt;48 dB(A) with sash closed\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eSensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eAudible\/visual alarms for breakthrough detection, temperature ≥40° C (104° F), fan failure and high sash position opening. At ≥60° C (140° F), all fans stop\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eSingle piece, tempered safety glass vertical-rising sash with cable pulley, sash weight and powder-coated aluminum sash handle and tracks with airflow openings. Sash stop at 16\" sash opening height on 4’ models and 13” sash opening height on 3’ models. Sash opens to 26\" high for loading\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eFactory-prepared for up to two electrical duplex receptacles and four service fixtures\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003e28.5\" high sightline from the work surface and header panel\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003ePower cord with plug\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eFixtured Models May Feature:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eTwo pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eOne pre-wired GFCI electrical duplex receptacle on lower right side\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eRequired Accessories (Not Included)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eNeutrodine Unisorb Filters (except HEPA only models which require HEPA filters). Number of filters required is determined by the width of the hood\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eWork Surface\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eBase Cabinet or Stand\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eOptions Available Include:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eHEPA filter\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eRegion-specific electrical plug configurations\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eService fixtures\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eSEFA 9, DHIII\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eSEFA 8, Cabinet Surface Finish Tests\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eModified ASHRAE 110\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eANSI Z9.5-2011\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eAFNOR NF-X 15-211\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eASTM E84-09C\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eUL Standard 61010-1\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eCAN\/CSA C22.2 No. 61010-1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eEstimated Shipping Weight: 535.0 lbs\u003cbr\u003eEstimated Shipping Weight metric: 242.7 kg\u003cbr\u003eDimensions: 48\" w x 37.7\" d x 54.2\" h\u003cbr\u003eDimensions metric: 121.9 x 95.8 x 137.7 cm\u003cbr\u003eElectrical: 115V, 50\/60 Hz, 10A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eAttributes:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAirflow Type: Bypass\u003cbr\u003eProduct Subcategory: General Chemistry\u003cbr\u003eNominal Width: 4'\u003cbr\u003eRegion: U.S. and Canada, International\u003cbr\u003eAir foil Type: Eco-Foil\u003cbr\u003eBlower Requirements: Integral blower included\u003cbr\u003eConformance: AFNOR NF-X, ANSI Z9.5, ASTM E84, CAN\/CSA C22.2, Modified ASHRAE 110, SEFA 9, UL 61010\u003cbr\u003eEnclosure Height: 54.2\"\u003cbr\u003eExterior Depth: 37.7\" (95.8 cm)\u003cbr\u003eLighting: LED\u003cbr\u003ePower Cord \u0026amp; Plug: 11.75' power cord with plug\u003cbr\u003eSash Type: Cable and pulley\u003cbr\u003eService Fixtures: 2\u003cbr\u003eStyle: Benchtop\u003c\/span\u003e\u003c\/p\u003e","brand":"Labconco","offers":[{"title":"Default Title","offer_id":39558116114507,"sku":"184410401","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0246\/1030\/8171\/products\/airobenchtop_184300202_left_rgb_web_20200706_dd6152bd-990b-4900-af23-e0880ef2d726.jpg?v=1634708256","url":"https:\/\/serfinitymedical.com\/products\/labconco-4-protector-airo-filtered-fume-hood-acid-sensor-115v-184410401","provider":"Serfinity Medical","version":"1.0","type":"link"}