{"product_id":"labconco-6-purifier-logic-class-ii-b2-biological-safety-cabinet-with-8-sash-opening-with-base-stand-303680141","title":"Labconco 6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8\" Sash Opening with Base Stand - 303680141","description":"\u003ch5\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eLabconco 6' Purifier Logic+ Class II B2 Biological Safety Cabinet with 8\" Sash Opening with Base Stand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003ePurifier Logic+ Class II, Type B2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. All models are NSF-Listed.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003csection id=\"product-description\" class=\"article article--margin largetext\"\u003e\n\u003cdiv class=\"grid-x\"\u003e\n\u003cdiv class=\"large-8 large-push-2 cell\"\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThese biological safety cabinets are designed to be hard ducted to the outside. During operation, room air is drawn into the top of the cabinet and through a supply HEPA filter. This filtered air flows downward through the work area. Room air is also drawn into the inlet grille located at the work access opening. All of the contaminated air passes through the exhaust HEPA filter. A dedicated exhaust system and remote blower discharge 100% of the filtered exhaust air from the laboratory. Since none of the air is recirculated, these biohazard cabinets may be used for work with agents treated with volatile toxic chemicals and radionuclides.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eAll Type B2 Biosafety Cabinets rely on external blowers (usually on the roof of a building) to exhaust 100% of the air entering the cabinet. If the building exhaust blower fails or is mistakenly turned OFF, the cabinet will become pressurized, resulting in contaminated air flowing from the work area into the laboratory. Perform a risk assessment regarding the type of work to be performed in the cabinet if there is an unintended loss of exhaust air. Consider a Class II, Type C1 BSC for greater protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eElectronically Commutated Motor (ECM)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eConstant Airflow Profile (CAP) airflow monitoring system\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eIntrinsically-safe negative pressure design\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eAir-Wave Entry System\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eContain-Air Negative Pressure Channel\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eSupply and exhaust 99.99% efficient HEPA filters. 99.999% efficient ULPA filters available\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eInterior-mounted, line-of-sight, color LCD with MyLogic OS displays filter life, status messages for alarm conditions and alerts. 8 languages available\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eBright, 90-150 footcandle, glare-free LED lighting located outside the contaminated work area\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eFully-closing, clear 1\/4\" tempered safety glass sash\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eCurved stainless steel inlet grille with Reserve-Air Secondary Airflow Slots\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eTwo electrical duplex receptacles. Flush-mounted-stainless steel with dampened hinges. Single outlets on 230V models. One outlet on each side, with ground fault interruption (115V)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eSmart-Start System user-programmable start up \u0026amp; shut down\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eLeak-tight stainless steel interior \u0026amp; powder-coated steel exterior\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eRemovable towel catch located under work surface\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eCode-activated electronic security lock\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003e22.6\" (57 cm) max. sash opening \u0026amp; 27.0\" (69 cm) viewing height\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003e10° Angled sash with counterbalanced, easy lift mechanism\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eADA-Compliant touchpad control on right side post\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eRemovable, seamless type 304 stainless steel, dished work surface with lift out knobs\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eNoise level \u0026lt;63 dBA\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eHeat load 990 BTU\/hour (4' models)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eNominal inflow velocity of 105 fpm (0.5 m\/sec)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eNominal downflow velocity of 55 fpm (0.3 m\/sec)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003e10' (3 m) power cord with plug\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eFive year warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eRequired Accessories (Not Included)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eSupporting base if non-welded stand option is not selected\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e4' and 6' widths\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eInternational electrical configurations\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eNon-welded, NSF-Approved, powder-coated steel telescoping base stand with fixed feet\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eAccessory Package: 254 nm UV lamp, ADA-compliant service fixture(s) with ball-type valve(s), and NSF-Approved Vacu-Pass™ Cord \u0026amp; Cable Portal\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eCell Logic+ packages specifically designed for use with microscopes and temperature-sensitive samples\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eETL listed\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eNSF International listed\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eCE Conformity marking (230V models)\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eISO 5 conditions per ISO 14644-1 and 2\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"color: #000000;\"\u003eADA-Compliant (controls and receptacles)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eEstimated Shipping Weight: 940.0 lbs\u003cbr\u003eEstimated Shipping Weight metric: 426.4 kg\u003cbr\u003eDimensions: 78.3\" w x 31.2\" d x 100.1-106.1\" h\u003cbr\u003eDimensions metric: 198.9 x 79.2 x 254.3-269.5 cm\u003cbr\u003eElectrical: 230V, 50\/60 Hz, 6A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eAttributes:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eProduct Subcategory: Class II, Type B2 Total Exhaust Safety Cabinets\u003cbr\u003eNominal Width: 6'\u003cbr\u003eProtection Type: Product and Personnel\u003cbr\u003eNominal Sash Opening: 8\" (20 cm)\u003cbr\u003eBase Stand: Included\u003cbr\u003eConformance: ADA, CE, NSF 49\u003cbr\u003eExhaust Volume: 1265 CFM\u003cbr\u003eLighting: LED\u003cbr\u003ePower Cord \u0026amp; Plug: China\/Australia, 230V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Labconco","offers":[{"title":"Default Title","offer_id":39563687428171,"sku":"303680141","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0246\/1030\/8171\/products\/10_43d6f481-e531-4be2-bb32-31bcc60fa9ab.jpg?v=1635163899","url":"https:\/\/serfinitymedical.com\/products\/labconco-6-purifier-logic-class-ii-b2-biological-safety-cabinet-with-8-sash-opening-with-base-stand-303680141","provider":"Serfinity Medical","version":"1.0","type":"link"}