{"product_id":"labconco-8-protector-echo-floor-mounted-filtered-fume-hood-115v-183817201","title":"Labconco 8' Protector Echo Floor-Mounted Filtered Fume Hood 115V - 183817201","description":"\u003ch5\u003e\u003cstrong\u003eLabconco 8' Protector Echo Floor-Mounted Filtered Fume Hood 115V\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eProtector Echo Filtered Floor-Mounted Fume Hoods provide the interior height needed for bulky apparatus with no ducting required. These hoods feature fully-closing, vertical-rising sashes. eGuard communication software offers real-time monitoring on the user’s phone or computer. From a remote location, data such as usage authorization, filter saturation detection, sash position and temperature may be observed and managed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Echo uses Neutrodine Unisorb Filters, the most comprehensive, safety-driven carbon filter available. This single molecular filter type can easily adsorb most chemicals and mixtures, taking the guesswork out of filter selection. Erlab-proven Neutrodine Filters are the heart of GFH Filtration Technology.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFloor-Mounted models include a fiberglass panelized liner and three exterior depths: 37.7”, 43.7”, and 55.7”. Models are available for carbon-only, carbon with acid sensor, carbon with formaldehyde sensor, or HEPA-only filtration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEco-Foil air foil with aerodynamic Clean-Sweep airflow openings\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCord-Keeper Slots on left and right side of air foil\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSingle piece, tempered safety glass vertical-rising sashes with cable pulley, sash weight and powder-coated aluminum sash handle and tracks with Clean-Sweep airflow openings. Upper sash stop at 16\" sash open height. Upper sash opens to 26\" high for loading chemicals. Lower sash opens up from floor to 55.2\" for transporting carts, drums and apparatus\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRemovable front and side panels, and front and interior service access panels for access to plumbing and electrical wiring\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eeGuard2 software communication\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSmart control module with wifi, Bluetooth and ethernet connectivity\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eFactory-installed command module, fan button and light button\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRear baffle\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBy-pass airflow design\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eGlacier white powder-coated steel exterior\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eChemical-resistant, fiberglass-reinforced, composite panel liner\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePre-wired vapor-proof LED lights for up to 63 foot candles rated for 50,000 hours: 2 lights per 4' model, 3 lights per 5' model, 4 lights per 6' model, and 5 lights per 8' model\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eFactory-prepared for up to two electrical duplex receptacles and six service fixtures\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRoughing prefilter: 2 each per 4' model, 3 each per 5' model, 4 each per 6' model, and 5 each per 8' model\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBuilt-in exhaust fans: 2 each per 4' model, 3 each per 5' model, 4 each per 6' model, and 5 each per 8' model, to maintain 60 fpm face velocity with only an upper sash opening height of 16”\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSound pressure of \u0026lt;60 dB(A) with sash at operating height and \u0026lt;48 dB(A) with sash closed\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSensor package for primary filter breakthrough of solvent and acid fumes, laboratory air quality, sash position, and temperature\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAudible\/visual alarms for breakthrough detection, temperature ≥40° C (104° F), fan failure and high sash position opening. At ≥60° C (140° F), all fans stop\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePower cord with plug\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFixtured Models May Feature:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo pre-plumbed service fixtures with forged brass valves, lower right side with brass tubing for gas and lower left side with copper tubing for cold water. Components for converting either or both fixtures to air and vacuum are provided. Inlet tubing is not provided\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eOne pre-wired GFCI electrical duplex receptacle on lower right side, and on 8' models only, one additional pre-wired GFCI electrical duplex receptacle on the lower left side\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequired Accessories (Not Included)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eNeutrodine Unisorb Filters (except HEPA only models which require HEPA filters). Number of filters required is determined by the width of the hood\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOptions Available Include\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHEPA filter\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eRegion-specific electrical plug configurations\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eService fixtures\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSEFA 9, DHIII\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSEFA 8, Cabinet Surface Finish Tests\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eModified ASHRAE 110\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eANSI Z9.5-2011\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAFNOR NF-X 15-211\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eASTM E84-09C\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eUL Standard 61010-1\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCAN\/CSA C22.2 No. 61010-1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEstimated Shipping Weight: 1,435.0 lbs\u003cbr\u003eEstimated Shipping Weight metric: 650.9 kg\u003cbr\u003eDimensions: 96\" w x 37.7\" d x 102.2\" h\u003cbr\u003eDimensions metric: 243.8 x 95.8 x 259.6 cm\u003cbr\u003eElectrical: 115V, 50\/60 Hz, 10A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAttributes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAirflow Type: Bypass\u003cbr\u003eProduct Subcategory: General Chemistry\u003cbr\u003eNominal Width: 8'\u003cbr\u003eRegion: U.S. and Canada, International\u003cbr\u003eAir foil Type: Eco-Foil\u003cbr\u003eBlower Requirements: Integral blower included\u003cbr\u003eConformance: AFNOR NF-X, ANSI Z9.5, ASTM E84, CAN\/CSA C22.2, Modified ASHRAE 110, SEFA 9, UL 61010\u003cbr\u003eEnclosure Height: 102.2\"\u003cbr\u003eExterior Depth: 37.7\" (95.8 cm)\u003cbr\u003eLighting: LED\u003cbr\u003ePower Cord \u0026amp; Plug: 19.5' power cord with plug\u003cbr\u003eSash Type: Cable and pulley\u003cbr\u003eService Fixtures: 2\u003cbr\u003eStyle: Floor-Mounted\u003c\/span\u003e\u003c\/p\u003e","brand":"Labconco","offers":[{"title":"Default Title","offer_id":39555753967691,"sku":"183817201","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0246\/1030\/8171\/products\/echofloormount_183637202_left_rgb_web_20200706_e5d93e80-928c-4f2a-954d-851e0834286a.jpg?v=1634543517","url":"https:\/\/serfinitymedical.com\/products\/labconco-8-protector-echo-floor-mounted-filtered-fume-hood-115v-183817201","provider":"Serfinity Medical","version":"1.0","type":"link"}