Nellcor - Pulse Co-Oximeter Battery Operated Audible and Visual Alarm - PM100N-HC
Questions? Speak with a specialist!
Chat with us!
Give us a call!
Email us!
This product may require 7-10 business days to process and prepare for shipping.
- Incorporates the latest Nellcor digital signal processing technology for accurate, reliable readings even during low perfusion, motion and other forms of signal interference
- Provides clinicians with real‑time information regarding their patients’ respiratory status, including continuous SpO2 and pulse rate monitoring and trending data
- Includes SatSeconds alarm management, a clinician‑controlled feature that can distinguish between real, clinically significant events and transient events by taking into account both the severity and the duration of any desaturation event
- Meets IEC 60601-1-11 standards for home health equipment compliant homecare and sleep study modes for safe and effective use of the monitor by lay users and in non‑hospital settings
- 1% to 100% SpO2, 20 to 250 beats per minute (bpm) pulse rate; 0.03% to 20% pulse amplitude measurement range
- Saturation - adult: 70% to 100% ± 2 digits; adult and neonate low sat: 60% to 80% ± 3 digits; neonate: 70% to 100% ± 2 digits; low perfusion: 70% to 100% ± 2 digits; adult and neonate with motion: 70% to 100% ± 4 digits
- Pulse rate - adult and neonate: 20 to 250 bpm ± 3 digits; low perfusion: 20 to 250 bpm ± 3 digits; adult and neonate with motion: 20 to 250 bpm ± 5 digits
- Power requirements: 100 to 240 V AC, 50/60 Hz, 45 VA; Fast-acting 2 A 32 V AC/DC, fast-acting 500 mA 32 V AC/50 DC fuse rating; lithium ion battery; minimum of five hours using new, fully charged battery with no alarms; optional 10-hour battery capacity
- Operating temperature - Instrument: 5 to 40 °C; Transport/storage temperature: 20 to 60 °C
- Operating humidity - 15% to 93% noncondensing
- -170 to 4877 Meter Operating altitude
- 82 X 155 X 255 mm Size
- Accuracy - Accurately assesses patients’ status with pulse oximetry measurements of ± 2 for 70% to 100% saturation, and low saturation accuracy of ± 3 for 60% to 80%
- Speed - reacts to patient status with technology that displays patient oxygenation and pulse rate more quickly than other technologies
- Motion tolerance - Accurately assesses patients’ status during periods of movement or noise, avoiding dropouts or delays, Covidien is the first company to receive FDA clearance for a motion tolerant pulse oximeter that is also compliant with ISO 80601-2-61
- Displays real time SpO2 and pulse rate measurements, plethysmographic waveforms and pulse amplitude
- SatSeconds alarm management
- Sleep Study mode
Stock Number : 1073254
Manufacturer # : PM100N-HC
Brand : Nellcor
Manufacturer : Medtronic MITG
Country of Origin : Unknown
Alarm Type : Audible and Visual Alarm
Application : Pulse Co-Oximeter
HCPCS : E0445
Power Source : Battery Operated
UNSPSC Code : 42181805
OXIMETER, PULSE BEDSIDE